Экспорт в страны RCEP | Импортные пошлины от 0% | Свяжитесь с нами для подробностей*

SEPPES high-speed cleanroom door and its interlocked steel door at a pharmaceutical facility

SEPPES Pharmaceutical Project

Interlocked Cleanroom Doors for a Pharmaceutical Factory

In China, SEPPES interlocked a high-speed cleanroom door with a steel door and added backup power and touchless activation for access to a 30 Pa pharmaceutical cleanroom.

Pharmaceutical Cleanroom Requirement

Planning a Pharmaceutical Cleanroom Entrance?

Send the opening dimensions, adjacent door details, pressure differential and required behavior during a power outage.

Request a Project Proposal

Two-Door Arrangement

How the Interlocked Cleanroom Doors Work

The interlock checks each door's closed status before permitting the other door to open. This one-door-at-a-time sequence helps avoid a direct air path between the spaces, much like airlock doors for clean rooms.

Steel Door

May open when the high-speed door is confirmed closed.

High-Speed Cleanroom Door

May open on a valid request when the steel door is confirmed closed.

  1. Step 1

    Enter through the steel door

    The steel door is permitted to open only when the high-speed door is confirmed closed. The high-speed door stays closed during passage.

    Steel: open High-speed: closed
  2. Step 2

    Confirm the steel door is closed

    The controls wait for the steel door's closed signal. A touchless opening request cannot override that check.

    Steel: closed High-speed: closed
  3. Step 3

    Open the high-speed door

    Once the steel door is confirmed closed, the controls can accept a valid opening request. The steel door remains inhibited until the high-speed door is confirmed closed again.

    Steel: closed High-speed: open

Rotary override selector: The project includes a separate selector for authorized use under the site's procedure when the normal interlock must be overridden. It is not the routine opening switch and does not mean both doors automatically open. Emergency behavior and the return to normal interlocking must be confirmed for the installed system.

The same closed-door rule applies in the opposite direction. For general airlock design context, see EU GMP Annex 1, section 4.13. This case does not establish a cleanroom grade or certification.

Конфигурация проекта

Backup Power, Touchless Access and Head-Box Sealing

Backup power for short outages

A cleanroom door with backup power has a temporary energy source when mains power is lost. Depending on the approved outage sequence, that power can let the controls complete a movement or move the door to a designated position, reducing the chance of it stopping partway through a cycle.

Automatic opening, backup duration and the number of supported movements are not specified for this project. The team should confirm which controls, locks and sensors remain powered; backup power for the door is not backup power for ventilation.

Touchless opening request

The touchless cleanroom door switch lets staff request opening without pressing a shared control. This removes a routine contact point, including for staff wearing gloves, and helps reduce opportunities for contact transfer.

The switch requests opening; it does not grant permission to open, bypass the steel door interlock or replace obstruction protection.

1.2 mm curtain and stainless steel closure

SEPPES fitted a 1.2 mm curtain and used stainless steel sheet to close the installation gap at the door head box. Closing that gap helps limit an unwanted path for air leakage around the frame.

The 30 Pa differential was a room condition, not a pressure rating or a pressure level generated by the door. The building's ventilation system manages the pressure difference.

Часто задаваемые вопросы

Cleanroom Door FAQs

What happens if the steel door is still open?

During normal operation, the high-speed door waits until the steel door is confirmed closed. The same rule applies in reverse: the steel door is not released while the high-speed door is open or has not been confirmed closed.

Does backup power automatically open the cleanroom door?

Not necessarily. Backup power provides temporary energy, but the approved outage sequence determines whether the door completes a movement, stays in position or moves to a designated position. Runtime and available cycles depend on the installed equipment and electrical loads.

What does the touchless switch do?

It sends an opening request without requiring staff to press a shared button. The request is still subject to the interlock. The switch does not replace cleaning procedures or door safety sensors.

Does the door create the 30 Pa pressure differential?

No. The 30 Pa figure describes the project condition. The ventilation system manages the pressure difference; the door sequence and closure around the head box help limit unwanted air exchange.